The 2012 edition of the life safety code nfpa 101 requires facilities to complete annual fire and smoke door inspection and testing.
Checklist fire door inspection report template.
This fire alarm inspection report template can help fire safety officers to easily.
To ensure the safety of a building s occupants regular checks must be performed on all fire doors.
Fire door assembly inspection checklist the 2007 and 2010 editions of nfpa 80 standard for fire do ors and other opening protectives section 5 2 inspections require all fire doors to be inspect ed not less than annually.
This may result in a requirement for the doors to be.
Fire doors are vital in keeping people safe in buildings they are an essential part of any structured fire safety plan.
Inspection and testing form nfpa inspection and testing 1 of 4 alarm notification appliances and circuit information quantity êêêêcircuit style bells horns chimes strobes speakers other specify.
Complete the report by providing a digital signature.
Our fire smoke door experts will provide a thorough inspection of all the doors in the building to ensure they are safe and complying with the nfpa code and prepare a detailed report on the condition and function of the fire door on your facilities.
Take photo evidence of non compliant doors and use iauditor s annotation feature to reveal damages and regulation breaches.
Check the door frame bolts hinges locks fire exit hardware door closers and other significant parts for defects in need of repair or replacement.
Manual fire alarm boxes ion detectors photo detectors duct detectors heat detectors waterflow switches supervisory switches other specify.
Fire door inspection form.
Fire doors basic guidance checklist introduction.
Door owner s monthly inspection checklist sectional doors location.
We are certified to perform detailed 13 points fire doors inspection.
The door operates smoothly and quietly without binding or scraping grinding noises.
Checks visual and operating checks only door door door door door door warning keep hands away from the door door operator safety devices operation.
Fire doors can only be effective though if they are maintained to the highest standards and are fit to perform their intended function in the event of a fire outbreak.
Chris i have no problem in checklists but in this area if you need a checklist wrt fire door inspection then maybe it should be left to some one that does not.
This detailed fire door inspection checklist can be used to survey the overall condition of fire doors.
Section 18 2 2 2 1 19 2 2 2 1 requires compliance with section 7 2 1 and section 7 2 1 15 2 requires compliance with nfpa 80 standard.